-40%

Dental Digital Image X-Ray Machine BLX-5(8PLUS)/ Digital RVG Image X-Ray Sensor

$ 401.27

Availability: 100 in stock
  • Model: VXS2121
  • Refund will be given as: Money Back
  • MPN: CGQ1180300411
  • Brand: Unbranded
  • Sensor Size: 26.5×32×11.7mm
  • Return shipping will be paid by: Buyer
  • Condition: New
  • Item must be returned within: 60 Days
  • Country/Region of Manufacture: China
  • All returns accepted: Returns Accepted
  • Restocking Fee: No
  • Intended Use/Discipline: Dental Laboratory

    Description

    X-ray Machine
    BLX-5(8PLUS)
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz

    and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees

    located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    TECHNICAL SPECIFICATIONS

    Tube Voltage
    60kV
    Tube Current
    1mA
    Time Exposure
    1~~9s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V

    220V
    Supply Frequency
    50Hz±1%
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 8000MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles

    '
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure

    Tooth
    Adult
    Child
    Central & Lateral
    0.8-1.2
    0.8-1.0
    Cuspid & 1st Bicuspid
    1.2-1.4
    1.0- 1.2
    Upper 5

    6
    1.6-1.8
    1.4-1.6
    Upper 7

    8
    3.0-3.5
    2.8-3.3.
    Lower 5

    6
    1.8-2.0.
    1.6-1.8
    Lower 7

    8
    2.0-2.5
    1.8-2.3
    Packing List:
    Main machine 1pcs
    Power line 1pcs
    User manual 1pcs
    Operation of the Main Unit :
    Upon receiving

    open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Install the blue ray tube to the foreside of the ball head

    then tighten it.
    Turn on the Power

    the pilot lamp will be light up.During this time

    the digital tube will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) Use the "SET"

    "+"

    and" -" buttons to reset the time as follows: press SET

    the pilot lamp above is illuminated

    the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture

    and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head

    tooth

    and tooth film steadily mutually plumb.
    After positioning

    use the ON/OFF on the main Unit

    to take pictures. (Notice: gently press 0.5 sec to turn it on)
    After exposure to the tube

    press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray

    so the dental films can be used again).
    Repeat step 6 to reset the picturing time.To repeat the picturing process

    please repeat steps 7 to 9.
    Turn the power off when the work is finished

    press POWER

    making sure the pilot lamp is off.Don't keep the machine long in standby mode.
    Points for Attention:
    Make sure the angle of film

    tooth

    and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    Remember to turn the power 0ff when work is done.
    Charge the battery if the machine cannot work and the red lamp lignt
    After turning the power on

    wait one minute before taking pictures

    this allows the ray to provide a steady output.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs

    it will not be able to carry out the normal work of filming.
    When taking pictures

    the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use

    so as not to damage the delicate component.
    We usually set the time between 3-8 seconds when taking pictures

    but the actual time of ray output is 0.2-0.5 seconds.
    If a situation occurs

    preventing the machine from taking regular pictures

    contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other requests accordance with the scope of the technical parameters.
    Please read the manual carefully before using.
    &
    X-ray Sensor
    Features

    The product is mainly composed of a sensor, an adaptor, a USB connection cable and workstation software. Working together with an X-ray equipment, the Product is intended to make X-ray radiography in dental clinics or veterinary clinics

    Sensor size Suitable for child

    adult single tooth

    and pets.
    Hardware Requirements

    Central Processor: Intel Core i3 or higher
    Internal Memory: 4GB or higher
    Hard Disk: 80GB or higher
    Display: 1280X1024
    USB interface: two
    Keyboard: One
    Mouse: One
    Software Requirement
    Operating Software

    Windows 7 SP1,8,10 32/64bit
    Runtime: .Net Framework 4.6 or higher, VC++ 2015
    Specification

    Product Name: Image RVG x-ray Sensor
    Product Model

    XVS2121
    Operating Voltage:5VDC
    Input power

    500mW
    Spatial Resolution

    ≥7Lp/mm
    Low contrast resolution

    Able to display holes with 1mm, 1.5mm, 2mm and
    2.5mm diameter on the 0.5mm-thick aluminium foil
    Image uniformity ≤2%
    Effective image area

    20.16*20.16mm
    Sensor Size

    26.5mm×32mm×11.7mm
    Adaptor Size

    60mm×40mm×29.2mm
    Total Cable Length: 3 m (sensor cable + control box cable to PC)
    Warranty:1 Year
    Accessory
    :
    Digital sensor: 1 Set
    USB cable :1 PCS
    U Disk: 1PCS
    Disposable protective sheath: 1 Box

    500

    silicon loop: 1 PCS
    Sensor holder: 1 PCS
    Aluminum plate:1 PCS (40*40*6mm)
    Shipping
    The goods you odered will be posted out in the second working day after the paymet has been made. (We will inform you via email if any delay occured due to holiday events.
    General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal.
    Payment
    We accept PayPal only.
    (The address in your paypal details will be used as the actual shipping adress, please make sure the adress is correct.)
    If you are planning on combining your items, please make sure that you wait until ALL auctions have ended before you visit the checkout. All items must be paid within 7 days.
    Feedback
    You feedback is VERY important to us!
    Please leave us positive feedback, an positive feedback will be automatically left for you once we receive your full payment. Please leave us with any concerns prior to leave negative feedback, as we can only correct issues when we are aware of them. We understand the concerns and frustrations you might have, and will try our best to resolve the isuues.
    Returns
    Exchanges are offered for items that are defective or damaged when received, although this is highly unlikely. After exchanges are made and have not resolved the issue, we will refund the cost of the merchandise.
    Defective items or problems with your order must be reported within 3 days after receiving. Please keep all packaging, documentation, packing list, etc. that came with your order. These will be used to verify claims if there is any problem with you.
    Restocking fee will be charged for returned items without original package or any quality problem.Please contact us for details before returning your package to avoid misunderstanding.
    IMPORTANT: Customer's item must be returned to our facility with the ROF (Return Order Form) at the buyers' shipping expense.
    Contact Us
    Serivce is our #1 priority at Dentistclub!
    If you contact us immediately after placing the order, we will make every effort to assist you with your change request. Unfortunately, we can not make changes or cancel an order once it has shipped.
    We offer the best items at the best prices. We strive to exceed all your expectations and put a smile on your face. Your experience will be a pleasant and effortless one when you buy at Dentistclub. We stand behind our products and pride ourselves on OUTSTANDING customer service. We guarantee that you will be delighted with your purchase or we will gladly and promptly issue you a refund or make things right!
    FDA Statement:
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not bid on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    Seller name:Dentistclub
    City,State:SHENZHEN,China
    Telephone number:0755-3889136